Feature Code Description
SPECIAL SEALS _ OMIT IF NOT REQUIRED
DIRECTIONAL CONTROL VALVE DG5S4 MANIFOLD OR SUBPLATE MOUNTING, SOLENOID CONTROLLED, PILOT OPERATED, SLIDING SPOOL, RATED PRESSURE 210 BAR (3000 PSI)
INTERFACE -04 04 - NFPA-D07 (ISO-4401-07)
SPOOL TYPES 2 CLOSED TO T ALL PORTS
SPOOL/SPRING ARRANGEMENT C SPRING CENTERED
ASSEMBLY _ OMIT FOR RIGHT-HAND ASSEMBLY. (FOR RIGHT-HAND ASSEMBLY P TO A WHEN SOLENOID `A+ IS ENERGIZED.)
MANUAL OVERRIDE OPTIONS _ PLAIN OVERRIDE SOLENOID END ONLY
RESPONSE TYPE _ STANDARD LOW SHOCK MODELS
SPOOL CONTROL MODIFICATIONS -2 PILOT CHOKE (DUAL) ADJUSTMENTS
PILOT PRESSURE _ INTERNAL PILOT PRESSURE
PILOT DRAIN -T INTERNAL PILOT DRAIN
PRESSURE PORT CHECK VALVE _ OMIT IF NOT REQUIRED
SOLENOID ENERGIZATION IDENTITY _ STANDARD ARRANGEMENT FOR ANSI B93.9 (ENERGIZE SOLENOID +A+ FOR FLOW P TO A PORT)
ELECTRICAL FLAG _ BLANK
SPOOL INDICATOR SWITCH _ OMIT OF NOT REQUIRED
SOLENOID INDICATOR LIGHTS _ OMIT IF NOT REQUIRED
ENCAPSULATED DIODE _ NO DIODE
P PORT ORIFICE _ OMIT IF NOT REQUIRED
A PORT ORIFICE _ OMIT IF NOT REQUIRED
B PORT ORIFICE _ OMIT IF NOT REQUIRED
T PORT ORIFICE _ OMIT IF NOT REQUIRED
DESIGN SPECIAL _ STANDARD BUILD