KBFDG5V Configuration
- Sequence 1 valve type (KBF) PROPORTIONAL VALVE WITH INTEGRAL AMPLIFIER & FEEDBACK ARRANGEMENT KBF 1
- Sequence 2 control type (D) DIRECTIONAL VALVE D 2
- Sequence 3 mounting (G) SUBPLATE MOUNTED G 3
- Sequence 4 operation (5) SOLENOID CONTROLLED PILOT OPERATED 5 4
- Sequence 5 pressure rating (V) MAX PRESSURE 310 BAR FOR 5 AND 350 BAR FOR 7,8,10 INTERFACE V 5
- Sequence 6 interface (8) NFPA D08, CETOP 8 6
- Sequence 7 spool type (2) P,A,B,T BLOCKED, (STANDARD FLOW PATHS) 7
- Sequence 8 spring arrangement (C) SPRING CENTERED, DUAL SOLENOID C 8
- Sequence 9 rated flow (375N) 375 L/MIN (99.4 USGPM) WITH METER IN & METER OUT 9
- Sequence 10 pilot supply (X) INTERNAL PILOT PRESSURE WITH PRESSURE REDUCER 10
- Sequence 11 pilot drain (0) EXTERNAL PILOT DRAIN _ 11
- Sequence 12 input signal (M2) 4-20 MA CURRENT DEMAND SIGNAL, ?10V VOLTAGE MONITOR 12
- Sequence 13 electrical connection (PE7) 7 PIN CONNECTOR WITH PLUG 13
- Sequence 14 coil voltage (H) 24V DC -H 14
- Sequence 15 tank port rating (1) 4 BAR MAXIMUM 1 15
- Sequence 16 design code No Preference -11 16
- Blank Blank Blank