Feature Code Description
CODE TITLE AAD 40.6 CM3/R [2.48 IN3/R] SERVO CONTROLLED VARIABLE DISPLACEMENT PUMP
INPUT SHAFT ROTATION R RIGHT HAND ROTATION (CW)
INPUT SHAFT C 13 TOOTH 16/32 EXTERNAL, DIA 21.81 [.858], SHAFT EXT 41.1 [1.62]
OUTPUT SHAFT H 35 TOOTH 48/96 EXTERNAL, DIA 19 [.750], TO BE USED WITH SPACER TO ACCEPT SHAFT EXT 24.4 [.96]
AUXILIARY MOUNTING FEATURES (REAR) A [2-BOLT A] SAE FLANGE SERIES 82-2
CHARGE PUMP 0 NO CHARGE PUMP
CHARGE PUMP RELIEF SETTING AND ROUTING 0 NO CHARGE PUMP
AUXILIARY PORT SIZE AND LOCATION D .750-16 UNF-2B SAE O-RING PORT - LEFT (C1) & RIGHT (C2) SIDES (HOUSING), LEFT SIDE PLUGGED
DRAIN PORT SIZE AND LOCATION D 1.0625-12 UN-2B SAE O-RING PORT - LEFT (D1) & RIGHT (D2) SIDES, RIGHT SIDE PLUGGED; THRU DRAIN INTO REAR AUXILIARY FLANGE (D3)
MAIN PORTS SIZE AND LOCATION 1 1.3125-12 UN-2B SAE O-RING PORT (A & B) - RIGHT SIDE
RELIEF VALVE SETTING FOR MAIN PORT A C THIS FEATURE IS PROPRIETARY OR UNPUBLISHED. PLEASE CONTACT YOUR DANFOSS REPRESENTATIVE OR A LOCAL DISTRIBUTOR FOR ASSISTANCE
RELIEF VALVE SETTING FOR MAIN PORT B C THIS FEATURE IS PROPRIETARY OR UNPUBLISHED. PLEASE CONTACT YOUR DANFOSS REPRESENTATIVE OR A LOCAL DISTRIBUTOR FOR ASSISTANCE
ADDITIONAL FUNCTIONS A BYPASS VALVE
CONTROL ASSEMBLY MA MANUAL CONTROL, WIDE BAND NEUTRAL, NEUTRAL LOCKOUT SWITCH
DESTROKE VALVE 1 DESTROKE WITH 12 VDC COIL & WEATHER PACK CONNECTOR
CONTROL SUPPLY ORIFICE (P) C DIAMETER 0.91 [.036]
CONTROL SERVO ORIFICE (S1 AND S2) B DIAMETER 0.81 [.032]
SPECIAL CONTROL OPTIONS 0 NO SPECIAL CONTROL OPTIONS
PAINT 0B BLACK PER SPEC 209-13B
SPECIAL FEATURES AC THIS FEATURE IS PROPRIETARY OR UNPUBLISHED. PLEASE CONTACT YOUR DANFOSS REPRESENTATIVE OR A LOCAL DISTRIBUTOR FOR ASSISTANCE
IDENTIFICATION 0 STANDARD
DESIGN CODE D D