Danfoss
4623-586
4623-586
Pumps - S3 46 VARIABLE PUMP CW
Model Code: ACA462340R0B00MAD000000030D05800B
Modify Configuration
Modify Configuration
Tools and Resources
Product Specifications
Feature | Code | Description |
---|---|---|
PRODUCT SERIES | ACA | HYDROSTATIC - HEAVY DUTY VARIABLE PUMP |
DISPLACEMENT | 46 | 75:28 CM3/R [4.594 IN3/R] AT 18 DEG |
TYPE | 2 | VARIABLE DISPLACEMENT PUMP |
DESIGN TYPE | 3 | SERIES 1 (MODELS 33-64) |
INPUT SHAFT | 40 | [1.50] DIAMETER TAPERED WITH [.3750] X [1.00] SQUARE KEY (MODELS 33-64) |
INPUT ROTATION | R | CLOCKWISE (RIGHT HAND) |
VALVE PLATE | 0 | STANDARD (V-GROOVE) |
MAIN PORTS | B | [1.00] - CODE 62 PER SAE J518 |
POWER LIMITER VALVE SETTING PORT A | 0 | NONE |
POWER LIMITER VALVE SETTING PORT B | 0 | NONE |
CONTROL | MA | MANUAL |
CONTROL SUPPLY ORIFICE (P) | D | 1;32 [.052] DIAMETER |
CONTROL ORIFICE - UPPER SERVO (S1) | 0 | NONE |
CONTROL ORIFICE - LOWER SERVO (S2) | 0 | NONE |
PRESS OVERRIDE | 0 | NONE |
PRESS SETTING FOR PRESSURE OVERRIDE | 0 | NONE |
CONTROL SPECIAL FEATURES | 0 | NO CONTROL SPECIAL FEATURES |
CHARGE PUMP | 0 | CHARGE PUMP INCLUDED |
AUXILIARY MOUNTING | 0 | NO AUXILIARY MOUNTING |
CHARGE PUMP DISPLACEMENT | 3 | 21:0 CM3/R [1.28 IN3/R] |
2ND DISPLACEMENT OF DUAL ELEMENT | 0 | NO DUAL ELEMENT |
CHARGE PRESSURE REL VALVE SETTING | D | 15 BAR [220 LBF/IN2] - STANDARD |
CHARGE PUMP SPECIAL FEATURES | 0 | NO CHARGE PUMP SPECIAL FEATURES |
SPECIAL PUMP ASSEMBLY FEATURES | 58 | 1350 SERIES END YOKE ASSEMBLED TO DRIVE SHAFT (POS 8,9 MUST BE CODE 40) |
PAINT AND PACKAGING | 0 | PAINTED PRIMER BLUE (STANDARD) |
IDENTIFICATION ON UNIT | 0 | STANDARD |
DESIGN CODE | B | B |