Vickers
02-396849
02-396849
Industrial Valves - DG5V-10-W-2C-2-T-M-PA5WL -B-10
Model Code: DG5V-10-W-2C-2-T-M-PA5WL-B-10
Tools and Resources
Product Specifications
Feature | Code | Description |
---|---|---|
SEAL TYPE | _ | (0) STADARD BUNA-NITRILE SEALS |
VALVE TYPE | DG5V | (DG5V) SOLENOID CONTROLLED, PILOT OPERATED DCV WITH 350 BAR RATING |
INTERFACE | -10 | (10) ISO 4401-10 INTERFACE, SIZE 10 |
PILOT VALVE | -W | NFPA - D10 (1SO - 4401 - 10)INTERFACE, SOLENOID CONTROLLED ,PILOT OPERATED (TWO -STAGE ) WITH HIGH PERFORMANCE PILOT (NPA-D03 SIZE PILOT ) |
REDUCER MODULE | _ | (0) NOT REQUIRED |
GAUGE PORT THREAD TYPE | _ | (0) GAUGE PORT 0.4375 - 20UNF, SAE THREAD |
SPOOL TYPE | -2 | (2) P,A,B,T BLOCKED |
SPRING ARRANGEMENT | C | (C) SPRING CENTERED |
BUILD ORIENTATION | _ | (0) STANDARD BUILD |
MANUAL OVERRIDE | _ | (0) PLAIN OVERRIDE IN SOLENOID ENDS ONLY |
RESPONSE | _ | (0) STANDARD LOW SHOCK MODELS |
SPOOL CONTROL | -2 | (2) PILOT CHOKE (DUAL) ADJUSTMENTS |
SPOOL MONITORING SWITCH | _ | (0) NOT REQUIRED |
PILOT SUPPLY | _ | (0) INTERNAL PILOT PRESSURE |
PILOT DRAIN | -T | (T) INTERNAL PILOT DRAIN |
CHECK VALVE | _ | (0) NOT REQUIRED |
SOLENOID IDENTIFICATION | -M | (M) FLAG WITH STANDARD BUILD AS PER ANSI B93 9 |
SOLENOID INDICATOR LIGHT | _ | (0) NO SOLENOID INDICATOR LIGHT |
DIODE | _ | (0) NO DIODE |
COIL VOLTAGE | -B | (B) 110V AC 50HZ / 120V AC 60 HZ |
DESIGN CODE | -10 | (10) DESIGN NUMBER |
SPECIAL FEATURE | _ | THIS FEATURE IS PROPRIETARY OR UNPUBLISHED. PLEASE CONTACT YOUR DANFOSS REPRESENTATIVE OR A LOCAL DISTRIBUTOR FOR ASSISTANCE |