Tools and Resources
Product Specifications
Feature Code Description
PRODUCT SERIES ACA HYDROSTATIC - HEAVY DUTY VARIABLE PUMP
DISPLACEMENT 64 105;4 cm3/r [6.431 in3/r] AT 18 DEG
TYPE 2 VARIABLE DISPLACEMENT PUMP
DESIGN TYPE 3 SERIES 1 (MODELS 33-64)
INPUT SHAFT 40 [1.50] DIAMETER TAPERED WITH [.3750] X [1.00] SQUARE KEY (MODELS 54-64)
INPUT ROTATION L COUNTERCLOCKWISE (LEFTHAND)
VALVE PLATE 0 STANDARD (V-GROOVE)
MAIN PORTS B [1.00] - CODE 62 PER SAE J518
POWER LIMITER VALVE SETTING PORT A 0 NONE
POWER LIMITER VALVE SETTING PORT B 0 NONE
CONTROL EJ ELECTRONIC PROPORTIONAL CONTROL 12 VOLT DC WITHOUT ELECTRONIC DRIVER
CONTROL SUPPLY ORIFICE (P) B 0;91 [.036] DIAMETER
CONTROL ORIFICE - UPPER SERVO (S1) 0 NONE
CONTROL ORIFICE - LOWER SERVO (S2) 0 NONE
PRESS OVERRIDE 2 INTERNAL PRESSURE OVERRIDE
PRESS SETTING FOR PRESSURE OVERRIDE J 310 bar [4500 lbf/in2]
CONTROL SPECIAL FEATURES 0 NO CONTROL SPECIAL FEATURES
CHARGE PUMP D CHARGE PUMP WITH EXTERNAL DISCHARGE PORT FOR 7/8-14 UNF SAE O-RING FITTING; WITH STEEL HEX PLUG
AUXILIARY MOUNTING 0 NO AUXILIARY MOUNTING
CHARGE PUMP DISPLACEMENT 3 21;0 cm3/r [1.28 in3/r]
2nd DISPLACEMENT OF DUAL ELEMENT 0 NO DUAL ELEMENT
CHARGE PRESSURE REL VALVE SETTING D 15 bar [220 lbf/in2] - STANDARD
CHARGE PUMP SPECIAL FEATURES 0 NO CHARGE PUMP SPECIAL FEATURES
SPECIAL PUMP ASSEMBLY FEATURES 00 NO SPECIAL FEATURES
PAINT AND PACKAGING A PAINTED FINISH BLACK
IDENTIFICATION ON UNIT 0 STANDARD
DESIGN CODE B B

Can’t find what you’re looking for? Submit a request