Processing Request...
Distributor Locator
Login
AMER •
English
Region
Global
AMER
APAC
EMEA
Language
English
Español
Français
Deutsch
Italiano
Português
日本語
简体中文
한국어
Products
Browse all products
Clutch and Brake (5800)
Connectors (7647)
Electronic Controls And Software (33)
Fittings (7307)
Hydraulic Hose (1057)
Industrial Hose (558)
LifeSense (33)
Cylinders (19054)
Filtration (12695)
Hydraulic Power Units (10)
Industrial Valves (21021)
Mobile Valves (6494)
Motors (10170)
Pumps (32993)
Screw-in Cartridge Valves (15512)
Steering Systems (1821)
Markets
Browse all markets
Aerospace
Buildings
Data centers
Food and beverage
Government
Healthcare
Machine building
Marine
Mining, metals and minerals
Mobile machinery and equipment
Oil and gas
Pharmaceuticals
Rail
Renewables
Residential
Utilities
Vehicles
Water and wastewater
Tools
Browse all tools
Product Configurator
Hose Assembly
Cross Reference
Crimp Specs
Wish List
2D/3D Models
Literature
Videos
Where to Buy
Calculators
Value Propositions
On Demand Presentations
Software Downloads
Batch Search
Mobile Valve Configurator
Coupling Comparison Tool
Fuel Calculator
Hydraulics Training
Where to Buy
Wish List
Batch Search
Subscribe
Based on your browser settings, you are viewing this site in Americas.
Click here
to see products offered in other regions.
Region
Global
AMER
APAC
EMEA
Language
English
Español
Français
Deutsch
Italiano
Português
日本語
简体中文
한국어
Close
Based on your browser settings, you are viewing this site in Americas.
Click here
to see products offered in other regions.
Close
Region
Global
AMER
APAC
EMEA
Language
English
Español
Français
Deutsch
Italiano
Português
日本語
简体中文
한국어
Eaton Powersource® Powering Business Worldwide
Subscribe
Distributor Locator
Login
AMER •
English
Region
Global
AMER
APAC
EMEA
Language
English
Español
Français
Deutsch
Italiano
Português
日本語
简体中文
한국어
Save and Email Items
Wish List
Batch Search
All
Clutch and Brake
Connectors
Cylinders
Electronic Controls And Software
Filtration
Fittings
Hydraulic Hose
Hydraulic Power Units
Industrial Hose
Industrial Valves
LifeSense
Mobile Valves
Motors
Pumps
Screw-in Cartridge Valves
Steering Systems
Category Matches
Part Number & Model Code Matches
MENU
Eaton Powersource® Powering Business Worldwide
Products
Browse all products >
Clutch and Brake (5800)
Filtration (12695)
Connectors (7647)
Hydraulic Power Units (10)
Electronic Controls And Software (33)
Industrial Valves (21021)
Fittings (7307)
Mobile Valves (6494)
Hydraulic Hose (1057)
Motors (10170)
Industrial Hose (558)
Pumps (32993)
LifeSense (33)
Screw-in Cartridge Valves (15512)
Cylinders (19054)
Steering Systems (1821)
Markets
Browse all markets >
Aerospace
Mobile machinery and equipment
Buildings
Oil and gas
Data centers
Pharmaceuticals
Food and beverage
Rail
Government
Renewables
Healthcare
Residential
Machine building
Utilities
Marine
Vehicles
Mining, metals and minerals
Water and wastewater
Tools
Browse all tools >
Literature
Product Configurator
Hose Assembly
Videos
Cross Reference
Where to Buy
Crimp Specs
Calculators
Wish List
Value Propositions
2D/3D Models
On Demand Presentations
Software Downloads
Batch Search
Mobile Valve Configurator
Coupling Comparison Tool
Fuel Calculator
Hydraulics Training
Where to Buy
Home
Products
Pumps
Piston Pumps
Piston Pumps-Open Circuit
PPOC-High Pressure
PPOC-DuraForce
HPR Configuration
Sequence 1
product identification
OPEN LOOP VARIABLE DISPLACEMENT PUMP
HPR
1
Sequence 2
displacement
075 CC
2
Sequence 3
rotation
RIGHT HAND (CW)
3
Sequence 4
mounting type
STANDARD
4
Sequence 5
input shaft
14 TOOTH 12/24 DP
5
Sequence 6
porting
ISO 6149 METRIC
6
Sequence 7
pump control
TL2 (POWER LIMITER)
7
Sequence 8
pressure compensator setting
NONE(H1L; E1L; TL2)
8
Sequence 9
load sensing differential pressure
20 BAR (LHY DEFAULT)
9
Sequence 10
power limiter setting
22KW
10
Sequence 11
pressure limiter remote control
NONE (LP; H1L; E1L;TL2)
11
Sequence 12
power limiter remote control
REMOTE POWER UP RATING (TL2; ETP ONLY)
12
Sequence 13
control solenoids
NONE
13
Sequence 14
noise optimization devices
SPU PRIMARY NOISE REDUCTION
14
Sequence 15
auxiliary pad and shaft definition
SAE J744 A PAD WITHOUT SHAFT COUPLING (DEFAULT)
15
Sequence 16
charge pump (internal gear) or tandem adapter
NONE
16
Sequence 17
auxiliary drive on internal gear pump
WITHOUT INTERNAL GEAR PUMP
17
Sequence 18
internal gear pump supply
NONE
18
Sequence 19
maximum displacement setting
CATALOG DISPLACEMENT
19
Sequence 20
operating speed
1200 R/MIN
20
Sequence 21
special features
SPLIT FLANGE AND JIC PREP KIT
21
Sequence 22
paint
ANTI RUST CONSERVATION OIL
22
Sequence 23
unit identification
EATON
23
Sequence 24
design code
FIRST
A
24
Blank
Blank
Blank
Reset
Reset
Reset
View
263
Results
Find 3D Model
Sequence 1
product identification
HPR – open loop variable displacement pump
Sequence 2
displacement
no preference
055 –
055 cc
075 –
075 cc
105 –
105 cc
135 –
135 cc
165 –
165 cc
210 –
210 cc
280 –
280 cc
Sequence 3
rotation
no preference
L –
left hand (ccw)
R –
right hand (cw)
Sequence 4
mounting type
no preference
0 –
standard
1 –
additional threads (105; 135)
2 –
additional holes (165;)
Sequence 5
input shaft
no preference
S1 –
14 tooth 12/24 dp
S2 –
17 tooth 12/24 dp
S3 –
13 tooth 8/16 dp
S4 –
15 tooth 8/16 dp
T2 –
23 tooth 16/32 dp
T3 –
27 tooth 16/32 dp
T4 –
33 tooth 16/32 dp
Sequence 6
porting
no preference
D –
din 3852
M –
iso 6149 metric
U –
sae unf
Sequence 7
pump control
no preference
A –
lp (pressure cut off)
B –
h1l (hydraulic override)
C –
e1l (electronic override)
D –
tl2 (power limiter)
E –
etp (electro-proportional - power limiter-pco)
F –
lep (ls - electro stroke limiter)
H –
po pressure comp only
Sequence 8
pressure compensator setting
no preference
00 –
none(h1l; e1l; tl2)
AA –
250 bar
AB –
350 bar
AC –
420 bar
AD –
280 bar
AE –
200 bar
AF –
222 bar
AG –
230 bar
AH –
380 bar
AK –
150 bar
AM –
220 bar
AP –
175 bar
AQ –
207 bar
AR –
210 bar
AS –
235 bar
AT –
276 bar
AU –
282 bar
AV –
283 bar
AY –
300 bar
AZ –
310 bar
BA –
360 bar
BE –
125 bar
BF –
103 bar
BG –
183 bar
BK –
172 bar
BN –
345 bar
BR –
241 bar
BX –
414 bar
CA –
165 bar
Sequence 9
load sensing differential pressure
no preference
00 –
none (pressure comp only)
AA –
16 bar
AB –
18 bar
AC –
20 bar (lhy default)
AD –
24 bar
Sequence 10
power limiter setting
no preference
000 –
none (lp; h1l; e1l; lep)
015 –
15kw
020 –
20kw
022 –
22kw
027 –
27kw
030 –
30kw
045 –
45kw
055 –
55kw
056 –
56kw
065 –
65kw
071 –
71kw
075 –
75kw
078 –
78kw
080 –
80kw
085 –
85kw
095 –
95kw
101 –
101kw
105 –
105kw
153 –
153kw
163 –
163kw
180 –
180kw
210 –
210kw
Sequence 11
pressure limiter remote control
no preference
0 –
none (lp; h1l; e1l;tl2)
D –
disabled (etp; lep only)
Sequence 12
power limiter remote control
no preference
0 –
none
1 –
remote power up rating (tl2; etp only)
Sequence 13
control solenoids
no preference
0 –
none
B –
amp / 24 v
C –
din / 12 v
D –
din / 24 v
F –
deutsch / 24 v
Sequence 14
noise optimization devices
no preference
0 –
none
1 –
spu primary noise reduction
Sequence 15
auxiliary pad and shaft definition
no preference
0G –
to add gear pump (see pos. 22,23)
AA –
sae j744 a pad without shaft coupling (default)
AB –
sae j744 a / ansi b92.1 16/32 - 9 teeth (a)
AD –
sae j744 a / ansi b92.1 16/32 - 13 teeth
AF –
sae j744 b / ansi b92.1 16/32 - 13 teeth (b)
AG –
sae j744 b / ansi b92.1 16/32 - 15 teeth (b-b)
AH –
sae j744 c without shaft coupling
AJ –
sae j744 c / ansi b92.1 12/24 - 14 teeth (c)
AL –
sae j744 c / ansi b92.1 16/32 - 23 teeth
AM –
sae j744 d without shaft coupling
AN –
sae j744 d / ansi b92.1 8/16 - 13 teeth (d)
AQ –
sae j744 d / ansi b92.1 16/32 - 27 teeth
AR –
sae j744 e without shaft coupling
AT –
sae j744 e / ansi b92.1 16/32 - 33 teeth
AU –
sae j744 e / ansi b92.1 8/16 - 15 teeth
AV –
sae j744 a / ansi b92.1 8/16 - 13 teeth (canfield regional)
Sequence 16
charge pump (internal gear) or tandem adapter
no preference
00 –
none
BA –
internal gear pump 16 cc
BB –
internal gear pump 22,5 cc
BM –
hpv/r 75 mounting preparation
BN –
hpv/r 105 mounting preparation
BP –
hpv/r 135 mounting preparation
BQ –
hpv/r 210 mounting preparation
BR –
hpv/r 280 mounting preparation
Sequence 17
auxiliary drive on internal gear pump
no preference
0 –
without internal gear pump
A –
sae j744 a / ansi b92.1 16/32 - 9 tooth (a)
C –
sae j744 b / ansi b92.1 16/32 - 13 tooth (b)
Sequence 18
internal gear pump supply
no preference
0 –
none
E –
external supply port
Sequence 19
maximum displacement setting
no preference
000 –
catalog displacement
048 –
48cc
055 –
55cc
123 –
123cc
150 –
150cc
190 –
190cc
210 –
210cc
Sequence 20
operating speed
no preference
A –
catalog pump rating
B –
1200 r/min
C –
1800 r/min
D –
2300 r/min
M –
1750 r/min
S –
1450 r/min
U –
1780 r/min
V –
1500 r/min
W –
2430 r/min
Sequence 21
special features
no preference
00 –
none
AG –
bleed drain for vertical mount
AJ –
remote pressure block ck00613 (regional)
AP –
shaft is 12.7mm longer that standard
AS –
split flange kit
BA –
0.8mm ls dampening orifice
BG –
modified e1l control (no solenoids)
BM –
split flange and jic prep kit
BP –
port adaptors (m22 x 1.5 iso to #12 male jic straight and m14 x 1.5 iso to #6 male jic straight) and coupling bagged and wired to the pump flange
BR –
ls control only, tl2 control disabled
BS –
m27 x 2 iso to #12 male jic straight drain port adapter and m14 x 1.5 iso to #6 male jic straight ls port adapter
BY –
power limiter disabled
CB –
eaton aeroquip iso to jic adapters for the case drain, ls port and z1 port
Sequence 22
paint
no preference
0 –
anti rust conservation oil
A –
primer blue
B –
primer ral 3009 red oxide
C –
primer + ral 9005 back
E –
paint yellow
Sequence 23
unit identification
no preference
A –
eaton
B –
eaton shanghai
Sequence 24
design code
A – first