ACL Configuration
- Sequence 1 product series HYDROSTATIC - HEAVY DUTY VARIABLE PUMP (SERIES 2) ACL 1
- Sequence 2 displacement 63;66 CM3/R [3.885 IN3/R] AT 18 DEG 2
- Sequence 3 input shaft 14 TOOTH 12/24 PITCH SPLINE 3
- Sequence 4 input rotation COUNTERCLOCKWISE (LEFTHAND) 4
- Sequence 5 valve plate V-GROOVE 5
- Sequence 6 main ports - (includes gage ports) 25,4 [1.00] - CODE 62 PER SAE J518 (OPPOSITE SIDE PORTS) 6
- Sequence 7 high press relief valve setting port a 379 bar [5500 lbf/in2] WITH 2 bar [29 lbf/in2] CHECK VALVE SPRING 7
- Sequence 8 high press relief valve setting port b 379 bar [5500 lbf/in2] WITH 2 bar [29 lbf/in2] CHECK VALVE SPRING 8
- Sequence 9 press override setting port a 345 bar [5000 lbf/in2] ADJUSTABLE RANGE 310-414 bar [4500-6000 lbf/in2] 9
- Sequence 10 press override setting port b 345 bar [5000 lbf/in2] ADJUSTABLE RANGE 310-414 bar [4500-6000 lbf/in2] 10
- Sequence 11 special pump features SERVO PISTON WITH EXTERNALLY ADJUSTABLE STOPS IN BOTH DIRECTIONS 11
- Sequence 12 control HYDRAULIC REMOTE 5-15 BAR [73-218 LBF/IN2] 12
- Sequence 13 control orifice supply (p) 1;32 [.052] DIAMETER 13
- Sequence 14 control orifice lower servo (s1) 2;59 [.102] DIAMETER 14
- Sequence 15 control orifice upper servo (s2) 2;59 [.102] DIAMETER 15
- Sequence 16 control special features NO CONTROL SPECIAL FEATURES 16
- Sequence 17 charge pump displacement 13;9 CM3/R [.85 IN3/R] (MODELS 054-089) 17
- Sequence 18 auxiliary mounting A-PAD, DUAL 2 BOLT MOUNT, NO SHAFT SEAL, 9 TOOTH 16/32 PITCH SPLINE 18
- Sequence 19 charge pump options REMOTE FILTER PORTS 19
- Sequence 20 charge pressure relief valve setting 24 BAR [348.1 LBF/IN2] 20
- Sequence 21 charge pump special features NO CHARGE PUMP SPECIAL FEATURES 21
- Sequence 22 paint and packaging No Preference 22
- Sequence 23 identification on unit STANDARD 0 23
- Sequence 24 design code A A 24
- Blank Blank Blank