- Sequence 3 input shaft rotation RIGHT-HAND ROTATION (CW) RIGHT SIDE SUCTION PORT, LEFT SIDE PRESSURE PORT 3
- Sequence 4 front mounting & input shaft 2 BOLT B (SAE J744-101-2) WITH 15 TOOTH 16/32 SPLINE (ANSI B92.1-1996 MOD.), SHAFT EXTENSION 46 [1.81] 4
- Sequence 5 main ports size & location REAR PORTS; SUCTION - 2.00 SAE J518 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61); PRESSURE - 1.00 SAE J518 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61) 5
- Sequence 6 drain port size & location 1.0625-12 UNF-2B O-RING PORT - TOP 6
- Sequence 7 diagnostic pressure ports NO DIAGNOSTIC PRESSURE PORTS 7
- Sequence 8 controller type PRESSURE AND FLOW COMPENSATOR WITH .4375-20 SAE O-RING LOAD SENSE PORT LEFT SIDE 8
- Sequence 12 control special feature NO CONTROL SPECIAL FEATURES 12
- Sequence 13 maximum displacement option STANDARD DISPLACEMENT (AS GIVEN IN CODE TITLE) 13
- Sequence 14 auxiliary (rear) mount & output shaft NO AUXILIARY MOUNTING FEATURES 14
- Sequence 16 pump special features MODIFIED ENDCOVER, CORNER REMOVED 16